Surge Guard Model 41390-RVC provides premium protection for your motor home and enhanced features over other transfer switches on the market
Total electrical protection for your RV
Protects your RV bumper to bumper from faulty park power
Optional easy to read LCD display constantly monitors and displays the condition of power being supplied to your RV
RVC communication allows instant display of voltage, current and fault conditions on an RVC compatible device
Automatic Transfer Switch Features
Transfers to generator power automatically when energized after 30 second delay
When both shore power and generator power are available, generator dominates after a 30 second delay
Once the generator is shut down, shore power activates after a 3-4 second delay
90A full rated contactor mounted on vibration isolators to ensure quiet operation
Over/under voltage protection
Contactor opens outside of 95V and 132V range after 9-second delay
Instantaneous trip at voltages above 140V and below 70V
Over/under frequency protection
Contactor opens outside of (54-70Hz) range after 30-second delay
Source power connection integrity
Contactor will not close or will open in the event of an open source conductor or miswired. L1, L2, Neutral and Ground
Brown/blackout protection 2 min 15 second delay is initiated after removal of power to ensure AC compressor head bleed off, feature can be disabled on remote. (optional)
Measures and displays both L1 & L2 load current independently
4-mode protection, 3,350 Joules
Energy capacity - 130,000 Amps peak
Fuse protected L1/L2 surge suppressors
Plain text display (Replace Surge) of open fuses indicating a failed MOV or open surge connection
Remote Panel Indicator (Optional) 40272
Continuous visual indication of source voltage (L1, L2) load current or diagnostics
Plain English display of faults. No cryptic error codes
LCD technology with automatic light-sensitive backlighting for easy reading in any ambient light condition
3rd Party Display Systems
RS232 proprietary output data stream for communication with external equipment